Read the preserved original
9 scanned pages · 0.5 MB · PDF
Bibliographic record
- Author
- Weston A. Price
- Catalogue date
- 1898
- Type
- Article / paper
- Subject
- Dental technology and radiography
- Publication year
- 1898
- Publication record
- Dental Cosmos, XL, 1898, 373-379; Ohio Dental Journal, XVIII, 1898, 164–172
- Historical bibliography
- Entry 3c
- Record ID
- wap-bib-3c
Catalogue notes
Listed in Price’s undated bibliography compiled after August 1933; individual custodian metadata has been checked; scan-level text verification remains pending.
Sources & provenance
Preservation details · custodian-16881.pdf
- Retrieved
- 2026-11-28T02:44:46+00:00
- Original URL
- Open source file
- SHA-256
5715ed667361ff03045b81bfd6695b673fa49454bbef8ff312aab1ff7ba8e24e- Local file
- custodian-16881.pdf
- Publication / reuse
- Original publication before 1931, as identified in custodian publication statement; original scan must be reviewed. US Copyright Office: https://www.copyright.gov/what-is-copyright/
Read searchable text
164 T RNAL.
Replace on the usc.: •,.,o a ..u .w rah the plate and die with one
covering of cheese cloth or thin paper, place in the Parker shot-
swaging device and swage.
The plate cannot now be removed from the die but by plac-
ing the same in hot water the metal will run out of the plate,
leaving it unchanged in shape .
It can now be polished and after transferring the relief from
the old die to the unused one, the plate is sprung onto it and
swaging with shot and melting the metal out as before will leave
the plate with an adaptation that cannot be procured by any
other method . . In taking an impression for metal castings, it .
shQuld be a little thicker than usual and any number of dies can
be made from the same impression, all of which will be alike .
The compounding of this alloy requires the greatest of care in
protecting it from the action of the air during the first melting
and in the manner of adding the metals as it never again
approaches the first heat except by carelessness, the metal, will
remain permanent in composition and working qualities indefi-
nitely.
The necessary expense of this alloy, which at first may seem
unreasonable, will be saved in the saving of time in one difficult .
case.
After two years of constant use of this metal I can positively
state that it will meet all the claims of this clinic.
W&
Some Hard Cases for Cataphoresis With Suggestions .*
BY WESTON A. PRICE, D .D .S ., CLEVELAND, OHIO .
THIS paper should be prefaced by a chapter on the general,
principles underlying and governing the practical application of
cataphoresis to the dental organs, which has been omitted .
This subject was chosen for two reasons : First, to bring out
a discussion upon this practical subject ; and second, to answer
some of the many inquiries that have come to me .
In the following, where the expression occurs that 11 the pain
Lmit is low," we mean that a very weak current produces pain,
* Paper read at the Ohio State Dental Society, December, 1 897.
THE 0HI0 DENTAL JOURNAL . 165
and when " high," a very strong current will be required before
pain is produced .
Suppose a bi-cuspid, with large buccal cavity, including the
loss of the buccal cusp, from a line extending from the sulcus to
the gingivm . The resistence of the tooth high, say 75000 ohms,
and the pain limit very low, say 0 .00002 amperes, or one fiftieth of
a milliampere of current the maximum the tooth will tolerate .
In this case, the distance to the pulp is short, and relatively the
resistance from the surface to the pulp at a point right over it is
very much less than at a point near the margin of the dentin ;
probably not more than 1-10 as great. In this particular case we
are to get anchorage grooves for a metallic filling, and of course
they must be made near the margins, otherwise the life of the
pulp would be endangered . The conditions existing are as fol-
1ows,-an extremely sensitive tooth with a very low pain limit,
and high resistance, which means that necessarily the process of
anesthesia will be slow, and more certainly it would take place
most rapidly in the path of least resistance, viz . : directly toward
the pulp. This is just the part that cannot be utilized, and the mar-
gins, where the retaining forms must be obtained, are but slightly
obtunded . Of course the obtunding of the whole tooth will be
secured with the anesthesia of the pulp, but that, in this case of
so low a pain limit, would be a very long operation ; probably not
less than thirty or forty minutes . Besides it is going away around
to produce what we want, viz . : the obtunding of the dentin at its
margins. We will suppose the decay to be removed if necessary
by a short treatment in the ordinary way . Now cover all the
dentin with oxyphosphate cement or chloropercha, except where
the retaining grooves are to be made, and apply as usual, and it
will be found that in very much less time, these grooves can be
cut painlessly . This simply concentrates the energy to the part
we wish to anesthetize.
ONE OF THE MOST DIFFICULT CONDITIONS TO COMBA T
is that of a secondary deposit of dentin, either in the pulp cham-
ber, or the tubuli . In these cases, and especially the latter, the
sensitiveness is sometimes very acute, even extreme, notwithstand-
ing the fact that the dentinal fibres have been reduced in size to
a very great extent. In typical cases of this condition the resist-
ance through the tooth to the pulp, runs up to hundreds of thou
sands of ohms .
166 THE OHIO DENTAL JO URNAt.
A typical case was as follows : A superior left cuspid in
which both mechaffiical and chemical abrasion had denuded the
entire occlusial surface almost to the pulp line. The dentin ex-
hibited a surface almost as hard and smoath as glass, and
extremely sensitive . The bite was such that no protection could
be put over the nearly exposed pulp, which was the source of
extreme discomfort and inconvenience to the patient, who was
about fifty years of age . Two things were indicated : the p-ro-
tection of the tooth by a gold filling and the previous destruction
of the pulp . Everything was adjusted as usual, and the current
allowed to run while inserting a large gold filling in another
tooth. The current was increased to 42 volts from dry cells and
the patient felt no sensation . A milliampere meter, reading in
fifths, showed no accurate reading, but the Rowland D . Arsonval
galvano-meter, which is adjusted to read in decimals of amperes,
registered 0.000093, making the resistance of the tooth aproxi-
mately 450,050 ohms. The current was allowed to run for an
hour, while completing the other operation, when to my great
surprise, only the surface, and to a very slight depth was anesthe-
tized, and below, that it was positively unbearable . Of course I
was chagrined and disappointed, and especially so that it bad
happened with this particular patient . A new appointment was
made, to give me an opportunity to study the case . The next
application was made as follows : The entire surface was covered
with cement, quite thick, and a small bur, about No . 5, used to
drill a hole through it, directly over the pulp . We were forcibly
reassured of the extreme sensitiveness of the dentin when the bur
reached it . The anode was placed in this small hole ; which was
a very small platibum wire twisted with some fibres of cotton,
and was kept moist with an aqueous solution of 'cocain nearly
saturated . The voltage was increased to 72 from dry cells, with-
out pain . The amperage was 0 .00013, showing the resistance to be
about 550,000 ohms ; the increase of resistance over the >first ap-
plication, is of course explained by the diminished cross sectional
area of the path through the dentin . In ten minutes I drilled
almost to the pulp without sensation, and reduced the resistance
just half, viz . : to 275,000 ohms . Another application was made
of 0 .00026 amp . at 72 volts, for fifteen minutes, when the entire
pulp was removed with the drill and a broach, without a particle
of sensation, and the operation completed at orice : This method
THE OHIO DENTAL JOURNAL. 167
comes into service very often, as for example the rapid anesthesia
of a pulp in any denuded and broken-down tooth, requiring to be
crowned, or where a great deal of sensitive surface must be opera-
ted upon, as in chemical abrasion of a molar . In this latter case,
the pulp may be anesthetized for a time, and not injured nor
approached, thereby allowing the tooth to be worked upon at will
for the time .
The other form of secondary deposit, viz . : within the pulp
chamber, thereby forming a dense protection, is occasionally the
source of much hindrance to cataphoresis . As these are best
demonstrated by actual cases, the following is a typical case : A
right superior lateral which had been the source of constant
neuralgia,for months, and extremely sensitive to thermal changes
applied to the tooth at any point ; caries was so extensive that
anchorage could not be had for a gold filling without using the
pulp chamber, which with the above abnormal conditions, indica-
ted the destruction of the pulp . Application was made while in-
serting another gold filling . The pain limit was found at 0 .00002
amperes, or 1-50 of a milliampere and 26 volts, making the resist-
ance 130,000 ohms . This was surprisingly high . When I under-
took to drill into the pulp chamber, I found it receded, and
although the current had been running long enough to anesthetize
perfectly, I found that directly toward the pulp it was still sensi-
tive, though in some directions around this point, there seemed to
be perfect anesthesia . This was apparently a perfect failure .
From the figures and the conditions, I decided after studying the
case, that the resistance to the pulp was greater than the resist-
ance to the margins around the tooth, and the current was prob-
ably mostly going in that direction instead of towards the pulp .
Accordingly the rubber cloth was forced up under the gum and a
piece of gutta-percha placed between the gum and the tooth
where the shortest circuit seemed probable, and another applica
tion was made with good success in a few minutes .
THE PAIN LIMIT .
It occasionally happens that we want to remove the pulp for
immediate filling, in a bicuspid or sometimes a molar . Probably
the patient has come some distance and it will be a great conve-
nience to complete the operation at the same sitting . Itfrequently
happens that after using cataphoresis for some time, which we
168 THE OHIO DENTAL JO URNAL .
think should be long enough . we try to drill out the pulp, and
find suddenly at' some point there is very definite sensation . Per-
haps we make another long application, and this point is but
slightly improved . This is certainly discouraging, and I confess
I have been quite inconvenienced by it. What is the explanation
of it ? Perhaps it is a crown cavity where we are sure our insula-
tion is perfect . I have never found just this condition in a single
rooted tooth . Time will not permit us to diqcuss in this paper
the conditions which determine the pain limit . It is a fact, how
a-thanerlyvoftwhre-doas
distinct and different pain limit from the others . It will not
follow that the one, with the lowest pain limit, or is the most sen-
sitive to the current, is getting the most current ; indeed it may
be quite'the reverse, as is easily demonstrated . In the case we
will suppose, which is like many I have detailed records of, the
resistance in the most sensitive root is probably several times that
in the other root, say it is ten times as great . Of course; then,
ten times as much current is passing through the other root, and
on account of the greater density of current, that root of least •
resistance is anesthetized much more rapidly . All the time the
total amount of current used is determined by the pain limit of
the tooth, which simply means, by the pain limit of the most sen-
sitive root, which in this case, is the one getting the least current .
As the process of anesthesia advances, it is not proportional in
the different roots, consequently
' the rise of pain limit is not pro
. Probably in one root it has advanced from 1 10 of a-portinal
milliampere to one-half in twelve minutes, while in another root
from 1-50 to 1-45 of a milliampere . Here, clearly, 'the root of
lowest pain limit, or greatest sensitiveness, is determining the rate
of increase for the-whole tooth, and long before this root is per-
fectly anesthetized, the other is so complete, that we have been
losing great quantities of energy to no avail, or probably to a dele-
terious effect at the apex of one of the other roots . I have almost
always found in these cases that after twelve or fifteen minutes I
could remove the pulp without sensation from one root of a tw6-
rooted tooth or probably two from a three-rooted tooth . Now
just here-lies our opportunity to save time . Plug these roots up
with some cotton and sandarac, or gutta-percha, and concentrate
the energy on the remaining root, and the results will be very
gratifying .
THE 0HI0 DESTAL TO URNAL. 169
One of this class was as follows : Tooth, lower left first per-
manent molar, patient about twenty-five. Large suppurating ex-
posure had been giving considerable trouble . Operation had to
be completed at the same sitting. On applying cataphoresis the
pain limit was reached at .12 milliampere or twelve one hundred
thousandths of an ampere . The voltage was 4 and the resistance
-33330 ohms . The medicament used was a saturated solution of
cocain in guaiacol, though I generally use hydrochlorate of cocain
in distilled water . On using for ten minutes the pain limit was
raised to .25 milliampere and the voltage to 8, making the resist-
ance of the circuit 32000 ohms . The contents of the pulp-chamber
were removed with a drill without sensation, except one place
which was over the anterior root ; a second application was made
when the pain limit was reached at 0 .23 milliampere, with a volt-
age of 5-3, making the resistance of the circuit 26840 ohms . On
examination I found the anterior root still sensitive, and no sen-
sation in the posterior root, even beyond the apex, which had a
large foramen . The tissue was entirely removed from this, and
the root filled with a gutta-percha plug, and a new application
made, when the pain limit was found at 0 .15 milliampere, with 9-3
volts, making the resistance of this root 62000 ohms . In eight
minutes the pain limit had raised so that the current was in-
creased to 0 .7 milliampere, and the tissue of this root entirely
removed without sensation, and both filled at once . I have had
this condition duplicated several times in two-rooted bicuspids,
and have used this treatment to good advantage .
DIFFICIILT CiASES .
Probably one of the most common difficult cases is found
where there is confined suppurative inflammation in the pulp, and
.in which the current produces pain apparently by the pressure of
the gas developed . These cases are very easily recognized with
the milliampere meter, for instead of the pain limit getting higher
it recedes . If it is not pronounced it will probably turn in a few
minutes and proceed normally, but if very marked lowering of the
pain limit is present, it has been almost always the case in my
experience that on removing the anode, and carefully raising the
residual decay over the nearest point to the pulp, pus will escape .
This is a very strong indication of this condition, and with a very
sharp excavator, the decay is easily raised without pain . After
170 THE OHFO DENTAL J0 URNAL.
the escape of the pressure, -the cataphoric application will be
usually normal .
IS COCAIN DISORGANIZED BY THE ACIDS OF PiFS ?
Considerable study has been made, to see if the organic acids-
of the pus did not disorganize the alkaloid cocain, thereby destroy-
ing its therapeutic action . In passing 0 .00025 amperes through a
layer of first 10 per cent . solution of cocain hydrochlorate, then a .
laver of pus and a layer of surface water, separated b,y porous par-
titions in a long glass tube, as also at the same time a series with
blood, and one with water instead of pus, for twenty-five minutes,
we found no great difference in the amount of cocain present in each,
though apparently some lessin the pus tube . I am not satisfied
yet as to the perfection of this test, having made but one . Some
times we get
CASES WHERE IT IS PRACTICALLY IMPOSSIBLE TO RETAIN THE ANODE ..
For example, a broken down bicuspid or lower molar with
large sensitive eap-)sure . The patient could not endure to have
an electrode held on the exposed pulp . A convenient method of
retaining it is, after drying ; lay a piece of dry cotton over the
point of exposure, and flow cement over it . As soon as it stiffens,.
puncture a hole through the cement to the dry cotton . Saturate
it through the hole with medicament and wedge with cotton the
small soft wire anode in the hole . This perfectly insulates the
tooth from the surrounding gum and clamp, and holds the anode
perfectly. I think it is seldom advisable to try to do two cavities
at onee ; have a double apparatus, and do them separately, it
saves lots of time.
MAJORITY OF FAILURES ARE FROM SIMPLE CASES .
The cases I have just cited ar`e quite exceptional and are only
a very few of the exceptional cases . However, in my judgment.
by far the great majority of failures come from the simple easy
cases through nothing more nor less than imperfect insulation .
Gentlemen, I do not believe there are a dozen operators in the
state, who in a score of cases actually get fifty per cent . of
the current they use through the tooth they, are obtunding . I
very often find ten times as much ' current leaking as is going
through the tooth . The fact is that putting a rubber over a wet
THE OHIO DENTAL .TOURiVAL . 17 1
tooth, and fastening it with a clamp, and perhaps a single or
double waxed ligature to assist in holding the rubber is not, ex-
cept in the rarest cases, an insulation to the current .
The ligature soon gets wet, the clamp touches the wet tooth
and gum, and if you will test one hundred of the cases adjusted
in this way, I am sure you will find fully 95 that will have much
less resistance than the average tooth . It is an easy matter to
test them ; of course a milliampere meter is essential . And by
the way, I believe the time is not far distant and should be here
now, when it will be considered positively malpractice for a den-
tist to use cataphoresis without a milliampere meter . It would
be just as reasonable to send a locomotive engineer out with his
load of human freight without a steam guage or a safety valve .
But sqme one says the pain limit is the safety valve . Oh, no, it
isn't . Suppose a nerve is saturated with cocain, what power has
it of crying out when a destructive amount of current is passing
through it? Let me cite a case : A large buccal cavity in superior
left third molar presented which had been acbing intensely and
had apparently a large congested exposure . Very sensitive to
suction and positively unbearable to touch . I agreed with the
patient that it should be devitalized, which I proceeded to do with
cataphoresis . The toothache stopped, and although I started with,
one-tenth of a milliampere of current, in ten minutes the pain
limit had raised to one milliampere. I removed anode and
took large bur to cut out the main portion of the pulp when
to my surprise it did not fall through . I examined and found the
aprarent exposed pulp to be a piece of an apple . On remov-
ing all of the decay there was no exposure . I filled, using a non-
conductor liberally beneath the filling. In just three months the
patient came tearing into the office holding his face with the reg-
ulation abcessed tooth . The current had killed the pulp . This .
was bad diagnosing, but showed that the current in excess de-
stroyed the pulp .
Cataphoresis in the hands of the lazy, reckless, unskilled den-
tist, will be a positive curse to humanity ; while in the hands of
the earnest, thoughtful, skillful dentist, it is one of the greatest .
blessings that has ever come to us .
SIICCESB WITH CiATAPHORESI S
is synonomous with competency, and this will always be the case .-
You show me in the coming decades a man who is practising den-
1 72 THE OHIO DENT.4L JOtTRNA'L.
tistry simply for what he can get oat, of it, while putting just' a~ ,
little as he can into it, and I will show you a man who isn't hav-
ing success with cataphoresis . Time will develop two things, viz . : .
a clear conception of all the phenomena of cataphoresis, and the
most consistent practical application of the process . If any critic
is unsuccessful the reflection will not be upon cataphoresis, but
entirely upon himself .
Is it not truly wonderful that,a subject which has taken
months and months of careful investigation on the part of some
earnest investigators to secure a few fundamental, principles, with
very accurate and delicate apparatus, could be weighed and appre-
ciated and its future prescribed by some others in a few weeks,
with very inferior apparatus . I mention this because I have taken
the trouble to investigate to find with what authority some critics
have spoken, and have found that scarcely any had milliampere
meters, and most had such crude apparatus as the present stage
of advancement would deem a guarantee of failure owing to their
deficiency . We know that many teeth have so delicate a sense
of pain to variation of current that they will respond with severe
pain to the variation of the two-bundred-thousandth of all
ampere, and some to much less . Now suppose we try to usesome
of the early instruments on this case . For example, a short
column of surface water, say five inches . This would have a'
total variation of about 5000 ohms . Now to give a variation of
current less than the above, at say .10 volts, the plunge would
have to drop less than the one-hundredth of, an inch through the
first inch, which was a mechanical impossibility as they were
adjusted . If it dropped one-tenth of an inch the current'would
raise away beyond "the pain limit and produce intense pain . They
could not give success in such cases, nor could any of the early
instruments, and I have not seen a modern type that has as fine
adjustment as very many teeth demand . The future must furnish
these two things : instruments of a greater total and more gradual
variation, and more knowlege, for as yet we scardely know the
alphabet of the subject . It was my purpose to publish a quantity
of data showing the extent of time and the amount of eurrent
required at the beginning and ending of each operation and size
of cavity and medicine used for a great variety of cases, but the
length of the paper will not permit .